TWRO SYSTEM, Rogen/ ROL - Industrial Reverse Osmosis system 200,000 ~ 900,000 GPD.

TWRO SYSTEM, Rogen/ ROL - Industrial Reverse Osmosis system 200,000 ~ 900,000 GPD

Designed to produce low dissolved solids water from tap or well water, these systems use high efficiency reverse osmosis membranes. The product water is used in applications such as semiconductor, boiler feed, pharmaceutical, municipal, water reuse, food processing, bottling, and a wide variety of other applications.

Standard Features

Available Options

• 8” TFC spiral wound membranes
• Stainless steel multi-stage pump with TEFC motor
• FRP membrane housings
• 5 micron cartridge prefilter
• PLC based control panel
• Programmable time delay and set points
• HMI screen
• Motor starter
• Low pressure switch
• High pressure switch
• Liquid filled pressure gauges
• Permeate conductivity monitor
• Permeate & concentrate flow meters
• Remote monitoring
• Feed water conductivity monitor
• Membrane cleaning skid
• Product tank level switch
• Feed pH monitor with sensor
• Feed ORP monitor with sensor
• Water and hour meters
• Chemical dosing systems
• Media prefiltration systems
• Ozonation and UV sterilization systems
• Water softeners
• Skid mounted with pre or post treatment
• Containerized RO systems

The ideal applications for brackish reverse osmosis systems include:

Metal Finishing
Beverage Production and
Bottled Water
Electronics
Pharmaceutical
Mining Industry
Chemical Blending
Safe Drinking Water
Rinse Water
Power Plants
Plating Operations
EDI Pre-treatment
Food and Beverage
Spot Free Product Rinse
Cooling Towers
Laboratory
Boiler Feed Water
Ice Manufacturing
Ion Exchange Pre-treatment

Operation Conditions:

• Max. feed water temperature: 42°C
• Equipment upgrade for TDS up to 5,000 ppm
• Hydrogen Sulfide must be removed
• Max. Silica tolerance: 25 ppm @ 60% recovery
• Feed water TDS: 0-2,000 ppm
• Operating pressure: 150 to 250 psi
• pH tolerance range: 3-11
• Max. Iron content: 0.05 ppm
• Feed water pressure: 20 to 80 psi
• Hardness over 1 GPG requires water softener
• Turbidity should be removed